Default admin password: admin

2.Attach the power cord and connect the LAN cable between the N199 and a PC. Don’t use a hub.

3.Turn on the N199 and check the front panel. The Power LED should glow blue after power button is pressed. Then, the Busy LED starts blinking orange for around 60 seconds. After that, the Busy LED turns off. If the Busy LED keeps blinking orange for more than 3 minutes, the firmware may be corrupted during improper firmware upgrade procedures. It means that the motherboard has malfunctioned and needs to be repaired.

4.Set the IP address of the PC as 192.168.1.111, and then access the Login page. Make sure the N199 and the PC is directly connected through a LAN cable, and not through a hub or a router.

5.Check if the Web Administration Interface shows up and works fine. Then, check if the system status is normal and the HDD Power LED works fine. If the results are positive, it means that the N199 is functioning normally. Otherwise, the N199 may be damaged.

6.Suppose that the N199 has been damaged. If the Power LED glows blue and both system and power fans work fine after power button pressed, the motherboard needs to be checked and repaired. Otherwise, the power supply unit has problems.

83

Page 83
Image 83
Thecus Technology Thecus N199 user manual