Troubleshooting (Groundsmaster 3000–D)
CAUTION
Remove all jewelry, especially rings and watches, before doing any electrical trouble- shooting or testing. Disconnect the battery cables unless the test requires battery voltage.
For effective troubleshooting and repairs, you must have a good understanding of the electrical circuits and components used on this machine (see Wiring Sche matics section of this chapter).
If the machine has any interlock switches
Starting Problems
Problem | Possible Causes |
|
|
|
|
Starter solenoid clicks, but starter will not crank | Battery charge is low. |
(if solenoid clicks, the problem is not with the Ignition | Battery cables are loose or corroded. |
module or its inputs). | |
| Battery ground to frame is loose or corroded. |
| Wiring at starter is faulty. |
| Starter solenoid is faulty. |
| Starter mounting bolts are loose or not supplying a |
| sufficient ground for solenoid. |
| Starter is faulty causing incomplete circuit for solenoid. |
|
|
|
|
Nothing happens when a start attempt is made. | Wiring to start circuits (see Wiring Schematics) is |
| loose, corroded, or damaged. |
| Battery is dead. |
| 20 ampere fuse to start relay or 10 ampere fuse to |
| ignition switch is blown. |
| Neutral switch is faulty or traction pedal is depressed. |
| Ignition switch is faulty. |
| Start relay is faulty. |
| Starter is faulty. |
|
|
|
|
Engine cranks, but does not fire. | Wiring to start circuits (see Wiring Schematics) is |
| loose, corroded, or damaged. |
| Ignition switch is faulty. |
| A high temperature condition exists, high temperature |
| switch is shorted, or the high temperature relay is |
| faulty. |
| Fuel stop solenoid is faulty. |
| Preheating unit or components inputing into it are |
| faulty. |
| Engine or fuel system is malfunctioning (see Chapter 4 |
| – Peugeot Diesel Engine). |
|
|
|
|
Electrical System | Page 6 – 6 | Groundsmaster |