Toro 3000D manual Coolant Level Sensor GM 3000-D, Disconnect connector from the sensor. Unscrew

Models: 3000 3000D

1 242
Download 242 pages 19.97 Kb
Page 131
Image 131

Coolant Level Sensor (GM 3000–D)

The sensor is located on the degassing box, which is on the upper left end of the engine. It energizes a red warn­ ing light when coolant level in the degassing box and ra­ diator is to low (Fig. 44).

1.Make sure engine is OFF. Remove start relay from the control center.

DANGER

Make sure engine and cooling system have cooled down prior to checking coolant system levels. Possible steam burns may occur when re- moving the pressure plug.

2.Make sure cooling system is full (see Check Cooling System in Chapter 4 – Peugeot Diesel Engine).

3.Disconnect connector from the sensor. Verify cir­ cuitry to the sensor at the connector using a jumper and multimeter.

A.Place ignition switch in RUN. Jumper from the pin for the tan wire to chassis ground, the red warn­ ing light should come on. Turn switch OFF.

B.Hold ignition switch in START. Battery voltage from the pin for the white wire to chassis ground should be indicated. Turn switch OFF.

C.Check continuity (1 ohm or less) from the pin for the black wire to chassis ground..

D.Replace light bulb or correct any problem circuit­ ry if necessary.

4.Reconnect connector to the sensor. Test sensor us­ ing the following steps:

A.Place ignition switch in RUN. The red warning light should be off. Turn switch OFF.

B.Hold ignition switch in START. The red warning light should be off. Turn switch OFF.

PRESSURE

 

PLUG

CONNECTOR

SENSOR

DEGASSING

BOX

Figure 44

ELECTRODES

 

Figure 45

 

5.

Disconnect connector from the sensor. Unscrew

 

sensor from box and dry electrodes. Reconnect connec­

 

tor to sensor. Test sensor using the following steps (Fig.

 

45):

 

 

 

A. Place ignition switch in RUN. The red warning

Electrical System

 

B. Hold ignition switch in START. The red warning

 

light should come on. Turn switch OFF.

 

 

light should come on. Turn switch OFF.

 

 

 

 

6.

Reinstall start relay to the control center.

 

7.

Replace sensor with new one if necessary.

 

8.

Disconnect connector from sensor. Install sensor to

 

box. Reconnect connector to sensor.

Groundsmaster 3000/3000–D

Page 6 – 25

Electrical System

Page 131
Image 131