Disconnect Cutting Unit From Traction Unit

Note: Implements are heavy and may require two people to handle.

1.Start tractor and raise deck to highest possible posi- tion and turn off engine.

2.Rotate ignition key to run position and move lift lever forward to lower cutting unit.

3.Remove hair pin cotters and clevis pins securing height–of–cut chains to rear height–of–cut brackets.

4.Raise seat and open needle valve. This allows lift arms to float freely.

5.Remove hair pin cotter and clevis pin securing latch cover to lift arm .

6.Loosen release lever by rotating it counterclock- wise.

7.Pivot release lever upward and remove shaft latch from slot in traction unit lift arm.

8.Pull rearward on lock collar to release drive shaft coupler from tractor.

9.Stay clear of lift arms and move deck away from tractor allowing lift arms to fall.

10.Secure hair pin cotter and clevis pin to height–of– cut chains for storage.

11.Close needle valve

1

Figure 15

1.

Height–of–Cut Chain

 

1

Figure 16

1. Needle Valve

15

3

2

4

Figure 17

1.

Latch Cover

4.

Traction Unit Lift Arm

2.

Release Lever

5.

Machined Surface

3.

Shaft latch

 

 

72 inch Cutting Units

Page 11 – 10

Groundsmaster 3000/3000–D

Page 214
Image 214
Toro 3000D manual Disconnect Cutting Unit From Traction Unit