Outdoor units (combination)

Rating

hp

22

 

 

22

 

Cooling only system MMY

 

AP2201T8

 

 

AP2211T8

 

Heat pump system MMY

 

AP2201HT8

 

 

AP2211HT8

 

Outdoor unit type

 

Inverter

Inverter

Inverter

Inverter

Inverter

Outdoor unit combination

 

 

 

 

 

 

cooling only MMY-MAP

 

0801T8

0801T8

0601T8

1201T8

1001T8

Outdoor unit combination

 

 

 

 

 

 

heat pump MMY-MAP

 

0801HT8

0801HT8

0601HT8

1201HT8

1001HT8

Cooling capacity

kW

61.5

 

 

61.5

 

Heating capacity

kW

69.0

 

 

69.0

 

Power supply

V-ph-Hz

400-3-50 ± 10%

400-3-50 ± 10%

400-3-50 ± 10%

400-3-50 ± 10%

400-3-50 ± 10%

Voltage range

V

380-415

380-415

380-415

380-415

380-415

Power input, cooling

kW

17.39

 

 

20.41

 

Power factor, cooling

%

95

 

 

95

 

Operating current, cooling

A

26.42

 

 

31.01

 

EER, cooling

kW/kW

3.54

 

 

3.01

 

Starting current

A

1.0

 

 

1.0

 

Power input, heating

kW

17.35

 

 

18.68

 

Power factor, heating

%

95

 

 

95

 

Operating current, heating

A

26.36

 

 

28.38

 

COP, heating

kW/kW

3.98

 

 

3.69

 

Starting current

A

1.0

 

 

1.0

 

Unit appearance

 

Silky shade (Munsell 1Y8.5/0.5)

 

 

 

Dimensions

 

 

 

 

 

 

Height

mm

1800

1800

1800

1800

1800

Width

mm

990

990

990

990

990

Depth

mm

750

750

750

750

750

Total weight - cooling only unit

kg

256

256

227

256

256

Total weight - heat pump unit

kg

258

258

228

258

258

Heat exchanger

 

Finned type

 

 

 

 

Sound power level

dB(A)

74.5

 

 

74.5

 

Sound pressure level

dB(A) at 1 m

61.5

 

 

61.5

 

Fan type

 

Propeller

Propeller

Propeller

Propeller

Propeller

Motor power input

kW

0.6

0.6

0.6

0.6

0.6

Air flow

l/s

2750

2750

2500

2917

2917

 

m3/h

9900

9900

9000

10500

10500

Compressor type

 

Hermetic

Hermetic

Hermetic

Hermetic

Hermetic

Motor power input

kW

2.3 x 2

2.3 x 2

1.4 x 2

4.2 x 2

3.1 x 2

Refrigerant charge R-410A*

 

 

 

 

 

 

Cooling

kg

11.0

11.0

8.0

11.0

11.0

Heating

kg

12.5

12.5

8.5

12.5

12.5

Pipework**

 

 

 

 

 

 

Suction line type - diameter

in

Brazed - 7/8

Brazed - 7/8

Brazed - 3/4

Brazed - 1-1/8

Brazed - 7/8

Liquid line type - diameter

in

Flare - 1/2

Flare - 1/2

Flare - 3/8

Flare - 1/2

Flare - 1/2

Balance pipe type - diameter

in

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Flare - 3/8

Maximum equivalent length separation

m

175

175

175

175

175

Maximum actual piping length

m

150 (if equivalent bend length is longer, equivalent length is standard)

 

Maximum total piping length

m

300

300

300

300

300

Maximum lift - indoor unit above/below***

m

40/50

40/50

40/50

40/50

40/50

Control wiring

 

Shielded wire 1.25 mm2 x 2 cores up to 2000 m

 

 

Central remote controller

 

Shielded wire 1.25 mm2 x 2 pieces up to 1000 m, 2.0 mm2 x 2 pieces up to 2000 m

 

Max. number of connectable indoor units

 

37

 

 

37

 

High-pressure switch

MPa

Off: 2.90/On: 3.73

 

 

 

 

Protection devices

 

Discharge temperature sensor, suction temperature sensor, compressor crankcase heater,

 

 

high-pressure switch, overcurrent sensor, high-pressure sensor, low-pressure sensor,

 

 

 

overcurrent relay

 

 

 

 

Operating range, cooling†

°C

-5 to 43 db

-5 to 43 db

-5 to 43 db

-5 to 43 db

-5 to 43 db

Operating range, heating†

°C

-20 to 16 wb

-20 to 16 wb

-20 to 16 wb

-20 to 16 wb

-20 to 16 wb

Rated conditions: Cooling: Indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db

Heating: Indoor air temperature 20°C db, outdoor air temperature 7°C db/6°C wb

The standard piping equals 5 m main pipe length plus 2.5 m branch pipe length.

*The amount does not cover extra piping lengths. Refrigerant must be added on-site in accordance with the actual piping length.

** The maximum total piping length is the sum of one-way piping lengths on the liquid side or gas side.

*** If the indoor unit is above, maximum lift is reduced to 30 m, if the height difference between indoor units exceeds 3 m.

† Please refer to page 24.