Toshiba HFC R-410A manual Indoor units Standard ducted units

Models: HFC R-410A

1 108
Download 108 pages 43.4 Kb
Page 49
Image 49
Indoor units

Indoor units

Standard ducted units

Model MMD-AP

 

0071BH

0091BH

0121BH

0151BH

0181BH

0241BH

0271BH

0301BH

0361BH

0481BH

0561BH

Cooling capacity*

kW

2.2

2.8

3.6

4.5

5.6

7.1

8.0

9.0

11.2

14.0

16.0

Heating capacity

kW

2.5

3.2

4.0

5.0

6.3

8.0

9.0

10.0

12.5

16.0

18.0

Electrical data

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

V-ph-Hz 230-1-50 (voltage range 220-240 V) - power supply to indoor unit only

 

 

 

 

Operating current

A

0.29

0.29

0.34

0.34

0.43

0.52

0.52

0.61

0.83

0.98

0.98

Power input

kW

0.033

0.033

0.039

0.039

0.050

0.060

0.060

0.071

0.107

0.128

0.128

Starting current

A

0.50

0.50

0.59

0.59

0.75

0.90

0.90

1.05

1.44

1.70

1.70

Unit appearance

 

Zinc hot dipping steel plate

 

 

 

 

 

 

 

 

Unit dimensions

 

 

 

 

 

 

 

 

 

 

 

 

Height

mm

320

320

320

320

320

320

320

320

320

320

320

Width

mm

550

550

550

700

700

1000

1000

1000

1350

1350

1350

Depth

mm

800

800

800

800

800

800

800

800

800

800

800

Unit weight

kg

28

28

28

32

32

43

43

43

55

55

55

Heat exchanger

 

Finned tube

 

 

 

 

 

 

 

 

 

Sound proofing/heat insulating material

 

Non-flammable insulation

 

 

 

 

 

 

 

 

Fan type

 

Centrifugal fan

 

 

 

 

 

 

 

 

 

Fan motor power input

W

120

120

120

120

120

120

120

120

120

120

120

Air flow

 

 

 

 

 

 

 

 

 

 

 

 

High

l/s

133

133

158

181

217

317

317

350

450

550

550

Medium

l/s

117

117

136

150

183

275

275

300

392

475

475

Low

l/s

95

95

111

133

150

242

242

242

333

414

414

Air flow

 

 

 

 

 

 

 

 

 

 

 

 

High

m3/h

480

480

570

650

780

1140

1140

1260

1620

1980

1980

Medium

m3/h

420

420

490

540

660

990

990

1080

1410

1710

1710

Low

m3/h

340

340

400

480

540

870

870

870

1200

1490

1490

Static pressure (factory setting)

Pa

40

40

40

40

40

40

40

40

40

40

40

Static pressure (max.)

Pa

100

100

100

100

100

100

100

100

100

100

100

Sound power level (high/medium/low)

dB(A)

43/41/39

43/41/39

44/42/40

44/42/40

45/43/41

46/44/42

46/44/42

47/45/42

49/47/45

51/49/45

51/49/45

Sound pressure level (high/medium/low)** dB(A)

30/28/26

30/28/26 31/29/27

31/29/27 32/30/28 33/31/29

33/31/29

34/32/29

36/34/32 38/36/32

38/36/32

Air filter

 

Standard long-life filter supplied

 

 

 

 

 

 

 

Controller

 

Remote controller

 

 

 

 

 

 

 

 

 

Connection pipes

 

 

 

 

 

 

 

 

 

 

 

 

Gas connection diameter

in

3/8

3/8

3/8

1/2

1/2

5/8

5/8

5/8

5/8

5/8

5/8

Liquid connection diameter

in

1/4

1/4

1/4

1/4

1/4

3/8

3/8

3/8

3/8

3/8

3/8

Drain connection, nom. dia (polyvinyl tube)

in

1

1

1

1

1

1

1

1

1

1

1

Panel dimensions

 

 

 

 

 

 

 

 

 

 

 

 

Height

mm

9

9

9

9

9

9

9

9

9

9

9

Width

mm

630

630

630

780

780

1080

1080

1080

1430

1430

1430

Depth

mm

500

500

500

500

500

500

500

500

500

500

500

Panel weight

kg

3.5

3.5

3.5

4.0

4.0

6.0

6.0

6.0

7.0

7.0

7.0

Rated conditions: Cooling: Indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db

Heating: Indoor air temperature 20°C db, outdoor air temperature 7°C db/6°C wb

*Cooling capacities and electrical data are measured at the conditions specified by JIS B 8615, based on the reference piping which consists of 5 m of main piping and 2.5 m of branch piping connected with 0 metre height.

**The sound pressure level is measured in an anechoic chamber in accordance with JIS B 8616. Normally the values measured in the actual operating environment become larger than the indicated values due to the effects of external sound.

49