Quiet mode is the system which, control the
revolving speed of indoor fan to work constantly at lower than speed L. In addition, noise level of indoor unit is less than usual.
Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less.
cooling load and less heating load condition. Because of the fan speed L- may cause not
enough the cooling capacity or heating capacity.
FILE NO. SVM-10020

Item

Operation flow and applicable data, etc.

Description

15. QUIET mode When the [QUIET] button is pressed, the fan of the

indoor unit will be restricted the revolving speed at speed L until the [QUIET] button is pressed once

again (cancel Quiet mode).

16. COMFORTCooling mode

 

 

 

 

 

 

 

 

The principles of comfort sleep mode are:

SLEEP

The preset temperature will increase as

Quietness for more comfortable. When

 

 

room temperature reach setting temperature

 

 

show on ECO operation (Item No. 9)

 

 

 

Save energy by changing room temperature

 

Press the [COMFORT SLEEP] button to

 

 

automatically.

 

 

choose the operating hours. Repeat

 

 

 

The air condition can shut down by itself

 

 

pressing to select the hours.

 

 

 

 

 

 

 

 

 

automatically.

 

 

(1hr, 3hr, 5hr or 9hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Remarks:

 

If the [COMFORT SLEEP] button is pressed

 

 

Comfort sleep mode will not operate in dry

 

 

again means cancel comfort sleep mode.

 

 

 

 

mode and fan only mode.

 

Heating mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

 

The preset temperature will drop down as

 

 

 

 

 

 

show on ECO operation (Item No. 9)

 

 

 

Press the [COMFORT SLEEP] button to

 

 

 

 

choose the operating hours. Repeat

 

 

 

 

pressing to setect thehours.

 

 

 

 

 

 

 

(1hr, 3hr, 5hr or 9 hr)

 

 

 

 

 

 

 

 

If the [COMFORT SLEEP] button is pressed

 

 

 

 

again means cancel comfort sleep mode.

 

 

 

 

 

17. One-Touch

One touch comfort is the fully automated operation

Operation condition for model to Europe
Comfort

that is set according to the preferable condition in

market

 

a region.

 

 

 

 

 

 

 

 

When an indoor unit receives "One Touch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comfort Signal" from the remote controller,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the indoor unit operates as following.

 

 

 

 

 

 

 

 

 

 

 

 

 

1)

Air conditioner starts to operation when

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

 

the signal is received, even if the air

 

 

 

 

 

AUTO

 

*AUTO/L

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

conditioner was OFF.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)

Operation mode is set according to room

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature, the same as AUTO mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3)

Target temperature is 75°F (24ºC).

 

 

 

 

 

 

 

 

 

 

 

Time after operation

 

 

 

0

 

12

 

25

 

4)

Louver position is set as stored position

 

 

 

 

 

 

starts (min)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the operating mode.

 

*AUTO/L: Fan operates depends on the setting

 

 

5)

Fan is controlled as followings.

 

temperature and room temperature.

 

 

 

During the One Touch Comfort mode if the indoor unit receives any signal with other operation mode,

the unit will cancel the comfort mode and operates according to the signal received.

43