FILE NO.
6. SPECIFICATIONS OF ELECTRICAL PARTS
No. |
| Parts name | Type | Specifications | |
|
|
|
|
|
|
1 | Fan motor |
| DC340V, 30W | ||
(for indoor) |
| ||||
|
|
|
| ||
|
|
|
|
| |
2 | Room temp. sensor | ( − ) | 10kΩ at 25°C | ||
|
|
|
| ||
3 | Heat exchanger temp. sensor | ( − ) | 10kΩ at 25°C | ||
|
|
|
|
|
|
4 | Louver motor |
|
| MP24Z3T | Output (Rated) 1W, 16 poles, DC12V |
|
|
|
|
|
|
No. | Parts name | Model name | Rating | ||
|
|
|
|
| |
1 | Reactor | L = 10mH, 16A | |||
|
|
|
|
| |
2 | Outdoor fan motor | DC340V, 40W | |||
|
|
|
|
| |
3 | Suction temp. sensor (TS sensor) | (Inverter attached) | 10kΩ (25°C) | ||
|
|
|
|
| |
4 | Discharge temp. sensor (TD sensor) | (Inverter attached) | 62kΩ (20°C) | ||
|
|
|
|
| |
5 | Outside air temp. sensor (TO sensor) | (Inverter attached) | 10kΩ (25°C) | ||
|
|
|
|
| |
6 | Heat exchanger temp. sensor (TE sensor) | (Inverter attached) | 10kΩ (25°C) | ||
|
|
|
|
| |
7 | Terminal block (5P) | 20A, AC250V | |||
|
|
|
|
| |
8 | Compressor | ||||
|
| ||||
|
|
| |||
|
|
|
|
| |
9 | Coil for PMV | DC12V | |||
|
|
|
|
| |
10 | Coil for | STF |
| ||
|
|
|
| ||
11 | Pressure SW. | 4.7 MPa | |||
|
|
|
|
|
– 20 –