FILE NO. SVM-10020

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.

 

Parts nameTypeSpecifications

 

 

 

 

 

 

1

Fan motor

 

15LKV-UL, 17LKV-UL

ICF-340U30-2

DC340V, 30W

(for indoor)

 

22LKV-UL

 

 

 

 

 

 

 

 

 

2

Room temp. sensor (TA-sensor)

( )

10kΩ at 25°C

 

 

 

 

3

Heat exchanger temp. sensor (TC-sensor)

( )

10kΩ at 25°C

 

 

 

 

 

 

4

Louver motor

 

 

MP24Z3T

Output (Rated) 1W, 16 poles, DC12V

 

 

 

 

 

 

6-2. Outdoor Unit

No.

Parts nameModel nameRating

 

 

 

 

 

1

Reactor

CH-57

L = 10mH, 16A

 

 

 

 

 

2

Outdoor fan motor

ICF-340UA40-2

DC340V, 40W

 

 

 

 

 

3

Suction temp. sensor (TS sensor)

(Inverter attached)

10k(25°C)

 

 

 

 

 

4

Discharge temp. sensor (TD sensor)

(Inverter attached)

62k(20°C)

 

 

 

 

 

5

Outside air temp. sensor (TO sensor)

(Inverter attached)

10k(25°C)

 

 

 

 

 

6

Heat exchanger temp. sensor (TE sensor)

(Inverter attached)

10k(25°C)

 

 

 

 

 

7

Terminal block (5P)

——

20A, AC250V

 

 

 

 

 

8

Compressor

15LAV-UL, 17LAV-UL

DA130A1F-27F1

3-phases 4-poles 1100W

 

 

22LAV-UL

DA150A1F-20F1

 

 

 

 

 

 

 

 

9

Coil for PMV

CAM-MD12TCTH-4

DC12V

 

 

 

 

 

10

Coil for 4-way valve

STF

 

 

 

 

 

11

Pressure SW.

ACB-4UB82W

4.7 MPa

 

 

 

 

 

– 20 –