FILE NO.
11-2. Primary Judgment
To diagnose the troubles, use the following methods.
1)Judgment by flashing LED of indoor unit
2)
3)Judgment of trouble by every symptom
Firstly use the method 1) for diagnosis. Then, use the method 2) or 3) to diagnose the details of troubles.
11-3. Judgment by Flashing LED of Indoor Unit
While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the contents of
Table 11-3-1
Indoor indication lamp flashes.
Which lamp does flash?
Item | Check | Block display |
| Description for |
code |
| |||
|
|
|
| |
A |
| OPERATION (Green) | ∙ | When turn ON power supply. |
| ∙ Power supply ON after failure or OFF. | |||
| Flashing display (1 Hz) | |||
|
| ∙ This flashing display is not air conditioner failure. | ||
|
|
| ||
B |
| OPERATION (Green) | Protective circuit operation for indoor P.C. board | |
| Flashing display (5 Hz) | |||
|
|
|
| |
C |
| OPERATION (Green) | Protective circuit operation for connecting cable | |
| TIMER (Yellow) | |||
| and serial signal system | |||
|
| Flashing display (5 Hz) | ||
|
|
|
|
OPERATION (Green)
DFILTER (Orange) Protective circuit operation for outdoor P.C. board Flashing display (5 Hz)
| OPERATION (Green) | Protective circuit operation for others | |
E | TIMER (Yellow) | ||
FILTER (Orange) | (including compressor) | ||
| |||
| Flashing display (5 Hz) |
|
NOTES :
1.Some check code will flash display of the indoor unit, when the air conditioner operates with some limitation.
2.Some check code will flash display of the indoor unit and stop operation of the air conditioner.
3.When item B and C or item B and apart of item E occur concurrently, priority is given to the block of item B.
4.The check codes can be confirmed on the remote controller for servicing.
– 69 –