(1)Operating precautions
1)When removing the front panel or the P.C. board, be sure to shut off the power supply breaker.
2)When removing the P.C. board, hold the edge of the P.C. board and do not apply force to the parts.
3)When connecting or disconnecting the connec- tors on the P.C. board, hold the whole housing. Do not pull at the lead wire.
(2)Inspection procedures
1)When a P.C. board is judged to be defective, check for disconnection, burning, or discolora- tion of the copper foil pattern or this P.C. board.
2)The P.C. board consists of the following 2 parts
a.Main P.C. board part:
DC power supply circuit (5 V, 12 V), Indoor fan motor control circuit, CPU and peripheral circuits, buzzer, and Driving circuit of louver.
b.Indication unit of infrared ray receiving Infrared ray receiving circuit, LED:
1.Turn on remote.
2.Setting requirment operation.
3.Push off remote.
4. Press [SET] button while pressing [CHECK] button |
| |
with a tip of a pencil. |
| |
5. Then press [ | ] button to transmit the signal to the |
|
indoor unit. | PRESET | FAN |
|
| TEMP |
| MODE | |
|
| COMFORT |
| QUIET | SLEEP |
| SWING FIX | |
| TIMER | CLR |
| ON | OFF |
| SLEEP | SET |
| °C/°F CHK | FILTER CLOCK |
This setting helps to shortern a compressor waiting period when operate cool, heat or dry mode. A compressor suddenly starts one order of Remote controller is received.