FILE NO.
1.If the lamps are indicated as shown B to E in Table
2.When the remote controller is set to the service mode, the indoor controller diagnoses the operation condition and indicates the information of the
If a fault is detected, all lamps on the indoor unit will flash at 5 Hz and it will beep for 10 seconds (Beep, Beep, Beep ... ). The timer lamp usually flashes (5 Hz) during
11-4-1. How to Use Remote Controller in Service Mode
1
2
Push [CHECK] button with a tip of pencil to set the remote controller to the service mode.
• “ ” is indicated on the display of the remote controller.
Push [ON ] or [OFF ] buttonIf there is no fault with a code, the indoor unit will beep once (Beep) and the display of the remote controller will change as follows :
PRESETFAN
TEMP
TEMP
| COMFORT |
QUIET | SLEEP |
SWING FIX | |
TIMER | CLR |
ON | OFF |
SLEEP | SET |
°C/° F CHK FILTER CLOCK
Alphanumeric characters are used for the check codes.
is 5. | is 6. |
is A. | is B. |
is C. | is D. |
• • •
•The TIMER indicator of the indoor unit flashes continuously. (5 times per 1 sec.)
•Check the unit with all 52 check codes ( to ) as shown in Table
•Push [ON ] or [OFF ] button to change the check code backward.
If there is a fault, the indoor unit will beep for 10 seconds (Beep, Beep, Beep ... ).
Note the check code on the display of the remote controller.
•
•All indicators on the indoor unit will flash. (5 times per 1 sec.)
3 Push [CLR] button.After service finish for clear service code in memory.
• “7F” is indicated on the display of the remote controller.
4 Push [] button to release the service mode.•The display of the remote controller returns to as it was before service mode was engaged.
Fig.