FILE NO.
9-3-2. How to Set the Auto Restart Function
To set Auto Restart Function, proceed as follows:
1.The power supply to the unit must be ON ; The function will not set or reset if the power supply is OFF.
2.Press the [RESET] button located on the front panel of the indoor unit for more than 3 seconds.
3.After 3 seconds, the unit beeps three times and the indicator blinks for 5 seconds.
• When the unit is standby (Not operating)Operation |
| Motions |
Press [RESET] button for more than | The unit is on standby. |
|
three seconds. (Less than 10 seconds) | ↓ |
|
|
| |
| The unit starts to operate. | The green indicator is on. |
↓After approx. three seconds,
The unit beeps three times | The green indicator flashes |
and continues to operate. | for 5 seconds. |
If the unit is not required to operate at this time, press [RESET] button once more or use the remote controller to turn it off.
RESET
• When the unit is in operationOperation |
| Motions |
Press [RESET] button for more than | The unit is in operation. | The green indicator is on. |
three seconds. (Less than 10 seconds) | ↓ |
|
|
| |
| The unit stops operating. | The green indicator is turned off. |
↓After approx. three seconds,
The unit beeps three times. | The green indicator flashes |
| for 5 seconds. |
If the unit is required to operate at this time, press [RESET] button once more or use the remote controller to turn it on.
RESET
• While the filter check indicator is on, the RESET button has the function of filter reset betton.
9-3-3. Power Failure During Timer Operation
∙If Timer operation is set and the power supply shut down accidentally, the previous Timer setting will be cancelled.
∙
– 46 –