10-7-4. Remote Controller A or B Selection Setting

When two indoor units are installed in the separated rooms, it is not necessary to change the selector switches.

Remote controller A or B selection

When two indoor units are installed in the same room or adjacent two rooms, if operating a unit,

2 units may receive the remote controller signal simultaneously and operate. In this case, the operation can be preserved by setting either one indoor unit or remote controller to B setting. (Both are set to A setting in factory shipment.)

The remote controller signal is not received when the settings of indoor unit and remote controller are different.

There is no relation between A setting/B setting and A room/B room when connecting the piping and cables.

Remote controller A- B selection

To separate using of remote controller for each indoor unit in case of 2 air conditioner are installed nearly.

Remote controller B Setup.

1.Push RESET button on the indoor unit to turn the air conditioner ON.

2.Point the remote controller at the indoor unit.

3.Push and hold CHK button on the remote controller by the tip of the pencil.

“00” will be shown on the display.

4.Push MODE during pushing CHK, “B” will show on the display and “00” will disappear and the air conditioner will turn OFF.

The remote controller B is memorized.

Note :

1.Repeat above step to reset Remote Controller to be A.

2.Remote controller A have not “A” display.

3.Detault setting of remote controller from factory is A.

“B” Display

“00” Display

PRESETFAN

Fig. 10-7-3

FILE NO. SVM-10020

Temperature unit °F - °C selection

1.Push and hold CHK button on the Remote Control by the tip of the pencil, "00" will be shown on the display.

2.Press SLEEP during pushing CHK

Note :

1.Repeat above step to reset Remote Controller to be °F.

2.Operation mode and temperature set will reset to

initial setting after change the temperature unit. 3. Default setting of Remote Control from factory

is °F.