When the installation plate is directly mounted on the wall

1.Securely fit the installation plate onto the wall by screws with the upper and lower catches, that hold the indoor unit, facing out.

2.To mount the installation plate on a concrete wall use anchor bolts. Drill the anchor bolt holes as illustrated in the above figure.

3.Install the installation plate horizontally and level.

CAUTION

When installing the mounting plate with mounting screw, do not use the anchor bolt hole. Otherwise, the unit may fall down and result in personal injury and property damage.

Installation plate

(Keep horizontal direction.)

Anchor bolt

Projection 9/16 in. (15 mm)

or less

Fig. 10-3-4

3/16 in3 (5 mm) dia. hole

7 Mounting screw Ø 5/32 in. x 1 in.

(4 mm x 25 mm)

Clip anchor (local parts)

Fig. 10-3-5

CAUTION

Failure to firmly install the unit may result in personal injury and property damage if the unit falls.

In case of block, brick, concrete or similar type walls, make 3/16 in. (5 mm) dia. holes in the wall.

Insert clip anchors for appropriate mounting screws .

NOTE :

Secure four corners and lower parts of the mounting plate with 4 to 6 mounting screws to install it.

FILE NO. SVM-10020

10-3-3. Electrical Work

1.The supply voltage must be the same as the rated voltage of the air conditioner.

2.Prepare a power source for the exclusive use of the air conditioner.

NOTE :

Wire type :

Power supply cord minimum AWG 14.

CAUTION

This appliance can be connected to a main circuit breaker in either of the following two ways.

1.Connection to fixed wiring:

A switch or circuit breaker which discon- nects all poles and has a contact separation of at least 1/8 in. (3 mm) must be incorporated in the fixed wiring. An approved circuit breaker or switch must be used.

2.Connection with power supply plug:

Attach power supply plug with power cord and plug it into wall outlet. An approved power supply cord and plug must be used.

NOTE :

Perform wiring work being sure the wire length is long enough.

10-3-4. Wiring Connection

How to connect the connecting cable

1.Open the air inlet grille upward.

2.Remove the screws securing the front panel.

3. Slightly open the lower part of the front panel,

then pull the upper part of the front panel toward you to remove it from the rear plate.

4.Insert the condit pipe (according to the local rule) into the pipe hole on the wall.

5.Remove the conduit mount by loosening the fixing screw. (Fig. 10-3-7)

6. Fix conduit pipe to conduit mount with lock nut.

7. Pull out the connecting wire through the conduit pipe

and process the wire. (Fig. 10-3-8)

8. Take out the wire to the front and fix it to the terminal

block. Be careful not to make mis-wiring (Fig. 10-3-9)

9. Firmly tighten the terminal screws to prevent them

from loosening. Tightening torque: 0.9 lbf. ft (1.2 N·m). After tightening, pull the wires lightly to confirm that they of not move.

10. Secure the connecting wire with the cord clamp.

11.Fix the conduit mount back to the body by fixing a screw.

12.Fix the front panel, terminal cover and air inlet grille on the indoor unit.

– 56 –