FILE NO. SVM-10020

 

 

 

 

Item

Operation flow and applicable data, etc.

Description

 

 

 

 

18. Hi-POWER([Hi-POWER] button on the remote controller

 

 

Modeis pressed)

 

 

 

When [Hi-POWER] button is pressed while the indoor

The Hi-POWER operation will be cancelled

 

unit is in Auto, Cooling or Heating operation, Hi-

when press [Hi-POWER] button again.

 

POWER mark is indicated on the display of the remote

 

 

 

controller and the unit operates as follows.

.

 

 

1. Automatic operation

 

 

 

 

 

The indoor unit operates in according to the

 

 

 

current operation.

 

 

 

2. Cooling operation

 

 

 

The preset temperature drops 2.0°F (1ºC)

 

 

 

(The value of the preset temperature on the

 

 

 

remote controller does not change.)

 

 

 

The indoor unit's fan speed level increase 1 tap

 

 

 

3. Heating operation

 

 

 

The preset temperature increases 3.5°F (2ºC)

 

 

 

(The value of the preset temperature on the

 

 

 

remote controller does not change.)

 

 

 

The indoor unit's fan speed level increase 1 tap

 

 

 

4. The Hi-POWER mode can not be set in Dry

 

 

 

operation

 

 

 

 

 

 

19. FILTER

When the elapsed time reaches 1000 hours after

 

 

Indicator

conditioner operation, the FILTER indicator lights.

 

 

 

After cleaning the filters, turn off the FILTER indicator.

 

 

 

How to Turn Off FILTER Indicator

 

 

 

Press [RESET] button on the indoor unit.

 

 

 

NOTE :

 

 

 

If [RESET] button is pushed while the FILTER indicator

 

 

 

is not lit, the indoor unit will start the automatic

 

 

 

operation.

 

 

.

44