| FILE NO. | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
No. | Part name |
|
|
|
|
|
|
|
| Checking procedure |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| ||||||||||||
1 | Room temp. (TA) sensor | Disconnect the connector and measure the resistance value with tester. | |||||||||||||||||||
| Heat exchanger (TC) sensor | (Normal temp.) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Sensor |
|
|
|
| Temperature |
| 10°C |
| 20°C | 25°C | 30°C | 40°C |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| TA, TC (kΩ) |
|
| 20.7 |
| 12.6 | 10.0 | 7.9 | 4.5 |
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | Remote controller | Refer to |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||
3 | Louver motor | Measure the resistance value of each winding coil by using the tester. |
|
| |||||||||||||||||
| MP24Z3T | (Under normal temp. 25°C) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| White | 1 | 1 |
|
|
|
|
|
|
|
|
| Position | Resistance value |
| ||||
|
|
| Yellow | 2 | 2 |
|
|
|
|
|
|
|
|
|
| 1 to 2 |
|
|
|
| |
|
|
| Yellow | 3 | 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 1 to 3 |
| 250 ± 20Ω |
| |||||
|
|
| Yellow | 4 | 4 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| 1 to 4 |
|
| ||||||
|
|
| Yellow | 5 | 5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 1 to 5 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 | Indoor fan motor | Refer to |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
No. | Part name |
|
|
|
|
|
|
|
| Checking procedure |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||
1 | Compressor | Measure the resistance value of each winding by using the tester. |
|
| |||||||||||||||||
| (Model : |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
| Red |
|
|
|
|
|
| Position |
|
| Resistance value |
| ||||||||
| ~ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| (Model : |
|
|
|
|
|
|
|
| Red - White |
|
|
|
|
|
|
| ||||
| ~ |
|
|
|
|
|
|
|
| White - Black |
| 0.92 to 1.02Ω | 0.88 to 0.98Ω |
| |||||||
|
|
| White |
|
|
|
| Black |
| Black - Red |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| at 20°C | |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
2 | Outdoor fan motor | Measure the resistance value of winding by using the tester. |
|
|
| ||||||||||||||||
| (Model : |
| Red |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Position | Resistance value |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Red - White |
| 20 to 22Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| White - Black |
| 20 to 22Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Black- Red |
| 20 to 22Ω |
| ||||
|
|
| White |
|
|
|
| Black |
|
|
|
|
|
|
|
|
|
| at 20°C | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
3 | Measure the resistance value of winding by using the tester. |
|
|
| |||||||||||||||||
| (Model : STF) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Resistance value |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1435 ± 144Ω |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| at 20°C | |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
4 | Pulse motor valve coil | Measure the resistance value of winding by using the tester. |
|
|
| ||||||||||||||||
| (Model : |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Position | Resistance value |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Red - White |
| 42 to 50Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| White - Orange |
| 42 to 50Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brown- Yellow |
| 42 to 50Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Brown- Blue |
| 42 to 50Ω |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| at 20°C | ||
|
|
|
|
|
|
|
|
|
| ||||||||||||
5 | Outdoor temperature sensor | Disconnect the connector, and measure resistance value with the tester. | |||||||||||||||||||
| (TO), discharge temperature | (Normal temperature) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
| sensor (TD), suction |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Temperature |
|
|
|
|
|
|
|
|
|
|
| |||||
| temperature sensor (TS), |
| Sensor |
|
|
| 10°C | 20°C | 25°C | 30°C | 40°C | 50°C |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| outdoor heat exchanger |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| TD (kΩ) |
| 100 |
| 62 | 50 | 41 | 27 | 18 |
| ||||||||
| temperature sensor (TE) |
|
|
|
|
|
| ||||||||||||||
|
|
| TO,TS,TE (kΩ) |
| 20.7 |
| 12.6 | 10.0 | 7.9 | 4.5 | — |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
– 87 –