U-Line 2275DWRWOL, 2275DWRWS, 2175WCOL, CLRCO2175, CO2175F, 2175RF, 2115WC Service and Repair, CLR2160

Models: 2175R 2115R 2115WC 2175/2275DWRR 2115WCOL 2175BEV 2175WC 2175RF CLR2160 CO2175/CO2275DWR CO2175F CLRCO2175 2275DWRWOL 2175WCOL 2275DWRWS

1 180
Download 180 pages 38.87 Kb
Page 17
Image 17
Figure 1. CLR2160

Section 3 - Service and Repair

.

R1: CONDENSER FAN

 

L

 

 

 

 

 

L

ICEMAKER EVAPORATOR

C

 

H

2276

 

 

HIGH PRESSURE

 

 

 

L

 

 

 

LOWPRESSURE

R4: WATER

 

 

C

 

L

TRANSITIONAL PRESSURE

SUPPLY

 

IN CAPILLARY TUBE

 

 

 

 

C

 

R5: WATER

 

 

C

CIRCULATION PUMP

 

 

 

 

 

L

 

R4: HOT GAS

 

 

BYPASS

 

 

VALVE

 

 

 

 

L

H

H

C

 

 

R3: COMPRESSOR

C

 

C

CONDENSER

 

 

RELAY

R1

R3

R4

R5

FUNCTION

FAN

COMP

HOT GAS /

CIRC PUMP

WATER IN

 

 

 

 

 

 

 

 

 

Mode 1:

ON

ON

OFF

ON

Ice Making

 

 

 

 

Mode 2:

ON

ON

ON

OFF

Ice Harvest

 

 

 

 

Mode 3:

OFF

OFF

OFF

OFF

Off

 

 

 

 

Mode 4:

OFF

OFF

ON/OFF

ON/OFF

Cleaning

 

 

 

 

Mode 5:

 

 

 

 

Water Fill &

OFF

OFF

ON*

OFF

Initial Start-Up

 

 

 

 

*Normal Start-Up lasts 3 minutes Note: R2, R6 and R7 not used

Figure 1. CLR2160

3-2

Page 17
Image 17