U-Line Service and Repair, 3-15, 2275DWRWS/2275ZWC, THERMISTOR OUTAGE EXCEPT DWRWS & 2275ZWC

Models: 2175R 2115R 2115WC 2175/2275DWRR 2115WCOL 2175BEV 2175WC 2175RF CLR2160 CO2175/CO2275DWR CO2175F CLRCO2175 2275DWRWOL 2175WCOL 2275DWRWS

1 180
Download 180 pages 38.87 Kb
Page 30
Image 30
Figure 10. 2275DWRWS/2275ZWC

Section 3 - Service and Repair

COMPRESSOR

 

COMPRESSOR

TOP

 

CONDENSER

TOP

COMPARTMENT

CONDENSER

 

COMPARTMENT

SOLENOID VALVE

THERMISTOR

THERMISTOR

SOLENOID VALVE

 

DRYER

 

DRYER

 

SOLENOID VALVE

 

SOLENOID VALVE

 

EVAPORATOR

 

EVAPORATOR

 

CAPILLARY TUBE

 

CAPILLARY TUBE

 

 

BOTTOM

 

BOTTOM

 

COMPARTMENT

 

COMPARTMENT

 

THERMISTOR

 

THERMISTOR

DRYER

 

DRYER

 

EVAPORATOR

 

EVAPORATOR

 

CAPILLARY TUBE

DWR052

CAPILLARY TUBE

 

DWR052

Figure 10. 2275DWRWS/2275ZWC

 

REVIEW THE FOLLOWING NOTES FOR GENERAL INFORMATION.

The unit is equipped with a four-minute compressor-off cycle.

The mullion heater is energized on the 2175DWRR whenever the T3 temperature falls below 90°F.

Normal defrosting is based on a time and temperature scale. See chart on page 3-40. Defrost ends if evaporator thermistor reaches stop point or maximum time, whichever comes first.

THERMISTOR OUTAGE (EXCEPT DWRWS & 2275ZWC):

If the refrigerator thermistor (T1) fails, the unit will continue to operate based on a preset time interval of 10 minutes on and 30 minutes off. The display will show “ER.”

If the evaporator thermistor (T2) fails, the unit will operate except it will defrost solely on time and ignore the temperature reading. The display will show “ER.” If the ambient thermistor (T3) fails, the unit will always have the mullion heater energized. The display will show “ER.”

If T1 is not working, unit runs a preset time interval — 10 minutes ON, 60 minutes OFF.

If T2 is not working, unit runs a preset time interval — 10 minutes ON, 60 minutes OFF.

If either T3 or T4 is open, use 90 minutes for defrost length. These errors do not show on the display; they are only logged on the board.

SERVICE

To check to see which relays are currently operating, hold the COLDER key and press the ON/OFF key three times. When entering the sequence, keep the COLDER key pressed until you completely release the ON/OFF key for the third time. The display will cycle through a series of numbers to tell which relays are energized. For example, if the unit was cooling the bottom drawer the display would show 11 20 31 40 50 61 70. The first number is the relay number. In the second number, 1 means ON and 0 means OFF. The relay information can be found in the Control Section.

THERMISTOR OUTAGE (DWRWS & 2275ZWC)

Each relay can also be turned on and off individually to determine

 

whether or not the board and component are operating. If a board is

3-15

Page 30
Image 30
U-Line 2175WCOL, 2275DWRWOL, 2115R Service and Repair, 3-15, 2275DWRWS/2275ZWC, THERMISTOR OUTAGE EXCEPT DWRWS & 2275ZWC