U-Line CO2175F, 2115R Door Alignment - Origins Models, Drawer Alignment, Service and Repair, 3-49

Models: 2175R 2115R 2115WC 2175/2275DWRR 2115WCOL 2175BEV 2175WC 2175RF CLR2160 CO2175/CO2275DWR CO2175F CLRCO2175 2275DWRWOL 2175WCOL 2275DWRWS

1 180
Download 180 pages 38.87 Kb
Page 64
Image 64
Door Alignment - Origins Models

Section 3 - Service and Repair

Door

Closer

Inserts

Boss

ULIN_0298a_A

Figure 41

8. Mount the door, install top hinge pivot pin.

Door Alignment - Origins Models

The unit’s door is aligned at the factory before shipment. However, its alignment could have been disturbed during shipment or during door panel installation.

ADJUSTING DOOR ALIGNMENT

1.Loosen (do not remove) top and bottom hinge screws (Figure 42 and Figure 43).

ULIN_0293_A

Figure 42

IMPORTANT

Properly aligned, the door’s gasket should be firmly in contact with the cabinet all the way around the door (no gaps).

CHECKING DOOR ALIGNMENT

1. Carefully examine the door’s gasket to assure that it is firmly in contact with the cabinet.

2. If the door is properly aligned, no further adjustment is necessary. If it is not, use the following procedure.

ULIN_0104_A

Figure 43

2. Align door squarely with cabinet. Make sure gasket is firmly in contact with cabinet all the way around the door (no gaps).

3. Tighten bottom hinge screws.

4. Tighten top hinge screws.

Drawer Alignment

3-49

Page 64
Image 64
U-Line CO2175F, 2275DWRWS, 2175WCOL Door Alignment - Origins Models, Drawer Alignment, Service and Repair, 3-49, Figure