U-Line 2175R, 2275DWRWS, 2175WCOL, 2275DWRWOL, CLRCO2175, CO2175F, CO2175/CO2275DWR Troubleshooting

Models: 2175R 2115R 2115WC 2175/2275DWRR 2115WCOL 2175BEV 2175WC 2175RF CLR2160 CO2175/CO2275DWR CO2175F CLRCO2175 2275DWRWOL 2175WCOL 2275DWRWS

1 180
Download 180 pages 38.87 Kb
Page 14
Image 14
Section 2 - Troubleshooting

 

 

 

 

 

 

Section 2 - Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cause

 

Remedy

 

 

 

 

 

 

 

Low ice production.

 

 

 

 

1.

Control set too cold.

1.

Adjust control warmer.

 

 

2.

Fan motor stalled.

2.

Replace fan motor.

 

 

3.

Ice cubes too large.

3.

Lower water fill adjustment.

 

 

4.

Dirty condenser.

4.

Clean condenser.

 

 

5.

Bypass valve stuck open (Frost Free units only).

5.

Replace bypass valve (Frost Free units only).

 

 

 

 

 

 

 

Not freezing (compressor and fan motors

 

 

 

 

operating).

 

 

 

 

1.

Little or no frost pattern on evaporator.

1.

Check for sealed system leak or restriction.

 

 

2.

Bypass valve stuck open (Frost Free units only).

2.

Replace bypass valve (Frost Free units only).

 

 

 

 

 

 

 

Not freezing (compressor not operating - fans

 

 

 

 

operating).

 

 

 

 

1.

Relay inoperable.

1.

Replace relay.

 

 

2.

Overload inoperable (open).

2.

Replace overload.

 

 

3.

Compressor inoperable.

3.

Replace compressor.

 

 

 

 

 

 

 

Not freezing (compressor and fans not operating).

 

 

 

 

1.

Power cord not plugged in.

1.

Plug in power cord.

 

 

2.

Unit turned off.

 

 

2.

Press On/Off button to turn unit on.

 

 

3.

Control panel inoperable.

 

 

3.

Replace control panel.

 

 

4.

Hold switch inoperable (open).

 

 

4.

Replace hold switch.

 

 

5.

Control inoperable.

 

 

5.

Replace control.

 

 

6.

Broken wire in freeze circuit.

 

 

6.

Repair or replace wiring.

 

 

7.

Ejector blades not in freeze position (12:00)

 

 

 

 

 

 

 

 

 

 

7.

Manually advance ejector blades to the 12:00 position (test ice

 

 

 

 

 

 

 

maker and limit switch).

 

 

 

 

 

 

 

Compressor overheating.

 

 

 

 

1.

Condenser air flow restricted.

1.

Remove restriction (clean condenser and grille).

 

 

2.

Condenser fan blade obstructed.

2.

Remove blade restriction.

 

 

3.

Condenser fan motor stalled.

3.

Replace fan motor.

 

 

4.

Compressor inoperable.

4.

Replace compressor.

 

 

 

 

 

 

 

Compressor will not stop operating.

 

 

 

 

1.

Temperature set too cold.

1.

Adjust temperature warmer.

 

 

2.

Control inoperable.

2.

Replace control.

 

 

3.

Control sensing bulb not sensing mold

3.

Fully insert bulb into ice maker tube. Rout bulb away from

 

 

 

temperature.

 

compressor discharge tube.

 

 

4.

Evaporator fan stalled.

4.

Remove obstruction or replace motor.

 

 

 

 

 

 

 

 

 

2-5