LOCALLY-INSTALLED DRAIN PUMP

Section 3 - Service and Repair

9.Unplug unit power cord from electrical outlet.

10.Reinstall back panel.

To connect to drain:

1.Attach the 5/8" ID drain connection on the back of the unit to a 5/8" OD rigid tube, using a worm clamp.

2.Attach the other end of the rigid tube to your 5/8" ID drain line with a worm clamp.

3.Insulate the drain line, if necessary, to prevent condensation.

LOCALLY-INSTALLED DRAIN PUMP

If a gravity drain connection is not possible, and you have not purchased the CLR2160 with factory-installed pump, we strongly recommend the use of the U-Line P60 drain pump. The U-Line P60 drain pump is available through your dealer, or direct from U-Line with complete installation instructions. If a pump other than the U- Line P60 drain pump is to be used, it must meet the following specifications:

It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power cord.

It must have overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.

It must have a minimum flow rate of 15 gallons per hour at 10 feet of lift.

It must have a sealed sump which does not allow water leakage in the case of a power outage, restricted drain or pump failure.

It must have a check valve in the discharge line to prevent waste water return to the pump.

It must have an overflow protection control which will shut off power to the ice maker in the event of a pump failure.

It must have an operating temperature range of 50°F to 110°F (10°C to 40°C).

U-CLR DRAIN KIT (AVAILABLE FOR PURCHASE)

Tools Required

1/4" Nut driver or flat 5/16" screwdriver

Side cutter

Copper tubing cutter

12" Level

9/16" Open end wrench

7/16" Open end wrench

Pliers

Materials Required

(10' or more depending on water supply location) 1/4" O.D. soft copper tubing

**(10' or more depending on drain location) 5/8" I.D. braid reinforced PVC drain tubing

**(3) 11/16" to 1-1/4" Clamp range worm drive hose clamps

**(1) Brass garden hose fitting (supplied with product)

**(1) Nylon barbed coupling for 5/8" ID hose

**(1) 5/8" to 7/8" adapter

**Depending on your model, your unit may have been packaged with these items. If you need to order these items, please contact U-Line and order Part # U-CLRDRAINKIT.

NOTE: These instructions are based on the U-Line recommendations and common industry practice. You must consult your local plumbing codes to ensure compliance. U-Line requires the use of copper cold water supply connection tubing. Plastic tubing should not be used.

1.Locate the desired cold water supply location. Attach a 1/4" copper line to this location and route the tubing to the appliance. Leave approximately 8' of water line to be coiled behind the appliance as shown (Figure 69). This water line should be looped into 2 coils. This will allow the line to flex when moving the appliance in and out of the opening.

ULIN_S_165

Figure 69

2.Locate the U-Line supplied garden hose fitting. Ensure the end of the copper tubing has been cut straight and is free of burrs. Slide the compression nut and ferrule onto the copper tubing as shown (Figure 70). Push the assembly completely into the garden hose fitting and tighten using the two wrenches. Wait to connect this assembly to the appliance until the drain connection is ready.

3-61