Section 3 - Service and Repair

1175R/1115R

1175WC/1115WC

1175BEV/ADA24R

COMPRESSOR/COIL SPECIFICATIONS

Figure 31. 1175R/1115R/1175WC/1115WC/1175BEVDANGER

Electrocution can cause death or serious injury. Burns from hot or cold surfaces can cause serious injury. Take precautions when servicing this unit.

Disconnect the power source.

Do not stand in standing water when working around electrical appliances.

Make sure the surfaces you touch are not hot or frozen.

Do not touch a bare circuit board unless you are wearing an anti-static wriststrap that is grounded to an electrical ground or grounded water pipe.

Handle circuit boards carefully and avoid touching components.

To measure the start winding resistance, measure across the C and S pins.

To measure the run winding resistance, measure across the C and R pins.

Also check S to R and you should get the sum of the run and start windings.

To ensure the windings are not shorted, check the S and R to ground.

OVERLOAD PROTECTOR

 

 

STARTING RELAY

 

 

 

 

C

 

S

R

RELAY COVER

CAPACITOR

 

 

 

ULIN_0368_A

Figure 31. 1175R/1115R/1175WC/1115WC/1175BEV

THERMISTORS

For all models, one type 2 thermistor is mounted to the sidewall.

Reed Switch

A reed switch is mounted to the underside of the cabinet and a magnet is mounted to the door. When the door is closed, the magnet trips the switch which turns the light and display off. For glass door models the display remains on unless toggled.

 

5400

5403

70075

70077

 

 

 

 

 

Voltage

115.0

220-240

115.0

115.0

 

 

 

 

 

Frequency

60.0

50.0

60.0

60.0

 

 

 

 

 

LRA

9.8

4.0

6.0

5.5

 

 

 

 

 

FLA

1.2

0.7

1.2

1.0

 

 

 

 

 

Start Winding

21.2

39.5

4.2

7.0

 

 

 

 

 

Run Winding

7.9

28.6

5.4

8.4

 

 

 

 

 

Capacitor

N/A

N/A

opt 15 uF

12uF

 

 

 

 

 

IMPORTANT

The U-Line ADA24R models employ both a 12VDC evaporator fan assembly and condenser fan assembly. The motors are powered by a 12VDC power supply located in the base of the unit. These fans are designed to operate in conjunction with the compressor and should be running whenever power is applied to the compressor electricals. These motors do not require external lubrication and do not overtighten the mounting screws upon installation (tab breakage could occur).

BLUE (NEUTRAL)

U-Line Part # 68103

100-240VAC (0.55AMP MAX)

Input

Output

Transformer/Power Supply

BROWN (HOT/LIVE￿￿

RED + (POSITIVE)

12VDC (1.7 AMP MAX)

BLACK - (NEGATIVE)