Section 3 - Service and Repair

Disposal Assembly

 

Air Gap

 

(Optional Hook-Up)

 

 

Waste

 

Cold

Hot

Water

Water

 

Shut-Off

 

Valve

 

ULIN_0572_A

Figure 65

Spigot Assembly

 

Air Gap

 

(Optional Hook-Up)

 

 

Waste

 

Shut-Off

 

Valve

 

Cold

Hot

Water

Water

 

ULIN_0573_A

Figure 66

IMPORTANT

Before installing your U-Line unit with factory- installed U- Line P60 pump, it is extremely important to check and test all hose connections at the drain pump. There is a possibility that hose connections may have loosened during shipment.

Manual backgroundWARNING

To prevent accidental electrocution, make certain that the floor surfaces surrounding the unit are dry whenever power is removed from, or applied to, the unit.

To check and test hose connections:

1.Make certain the unit is not plugged into an electrical outlet.

2.Carefully push the power cord grommet through the hole in the back panel (Figure 67).

Screws

 

Back

 

 

Panel

 

Grommet

 

 

Drain

Water

 

Connection

Power

Fitting

 

Cord

 

ULIN_0574_A

 

 

Figure 67

3. Remove 12 screws and back panel.

Manual backgroundWARNING

Back panel serves as a guard. DO NOT put your hands inside the ice maker cabinet or attempt to touch any components except the discharge tube during testing. Failure to follow this warning could result in serious personal injury or death.

4.Check that the clamps and hose connections are tight at the following areas (Figure 68):

Discharge tube (A)

Drain tube (B)

Vent tube (C)

B

B

C

C

 

A

Back View

Side View

 

ULIN_0575_A

Figure 68

5.Place a suitable container beneath the pump’s discharge tube. (The bucket must be able to hold a minimum of one gallon.)

6.Plug the ice maker power cord into a properly grounded, polarized electrical outlet.

7.Verify pump operation by pouring one gallon of water into the ice storage bin of the ice maker. The pump should energize and pump the water into the container.

8.At this time, verify that all tube and clamp connections are tight and leak free.