Refrigeration System Diagnosis Guide

Section 3 - Service and Repair

Refrigeration System Diagnosis Guide

System

Suction

Suction

Compressor
Condenser
Capillary
Evaporator
Wattage
Condition

Pressure

Line

Discharge

 

Tube

 

 

 

 

 

 

 

 

 

 

Normal

Normal

Slightly below

Very hot

Very hot

Warm

Cold

Normal

 

 

room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

Overcharge

Higher than

Very cold -

Slightly warm

Hot to warm

Cool

Cold

Higher than

 

normal

may frost

to hot

 

 

 

normal

 

 

heavily

 

 

 

 

 

 

 

 

 

 

 

 

 

Undercharge

Lower than

Warm -

Hot

Warm

Warm

Extremely cold

Lower than

 

normal

near room

 

 

 

near inlet -

normal

 

 

temperature

 

 

 

outlet below

 

 

 

 

 

 

 

room

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

Partial

Somewhat

Warm -

Very hot

Top passes

Room

Extremely cold

Lower than

Restriction

lower than

near room

 

warm -

temperature

near inlet -

normal

 

normal -

temperature

 

lower passes

(cool) or colder

outlet below

 

 

in vacuum

 

 

cool (near room

 

room

 

 

 

 

 

temperature

 

temperature

 

 

 

 

 

due to liquid

 

backing up

 

 

 

 

 

 

 

 

 

Complete

In deep

Room

Room

Room

Room

No

Lower than

Restriction

vacuum

temperature

temperature

temperature

temperature

refrigeration

normal

 

 

(cool)

(cool)

(cool)

(cool)

 

 

 

 

 

 

 

 

 

 

No Gas

0 PSIG

Room

Cool to hot

Room

Room

No

Lower than

 

to 25"

temperature

 

temperature

temperature

refrigeration

normal

 

 

(cool)

 

(cool)

(cool)

 

 

 

 

 

 

 

 

 

 

DEFROST INFORMATION - ALL MODELS

Model

Hours Between Defrost Time

Length/min

Stop Point
(Runtime) (Adjustable)

 

 

 

 

 

 

 

2175R

6

90

42°

 

 

 

 

2115R

6

90

42°

 

 

 

 

2175WC

6

90

45°

 

 

 

 

2115WC

6

90

45°

 

 

 

 

2175BEV

6

90

42°

 

 

 

 

2175/2275DWRR

6

90

42°

 

 

 

 

CO2175F

12

18*/45

42°

 

 

 

 

2175RF

12

18*/45

42°

 

 

 

 

CO21752275DWR

12

18*/45

42°

 

 

 

 

CLRCO2175

6

90

42°

 

 

 

 

2275DWRWS

12

90

45° (both drawers)

 

 

 

 

2275ZWCS/2275ZWCOL

12

75

45° (both zones)

 

 

 

 

1115R

4

60

-

 

 

 

 

1175R/ADA24R

6

45

-

 

 

 

 

1115WC

6

45

-

 

 

 

 

1175WC

6

45

-

 

 

 

 

1175BEV

6

45

-

 

 

 

 

3-41