U-Line 2175R/2115R 2175WC/2115WC 2175BEV, 2175DWRR/2275DWRWS 2275ZWC, Includes Overlay Models

Models: 2175R 2115R 2115WC 2175/2275DWRR 2115WCOL 2175BEV 2175WC 2175RF CLR2160 CO2175/CO2275DWR CO2175F CLRCO2175 2275DWRWOL 2175WCOL 2275DWRWS

1 180
Download 180 pages 38.87 Kb
Page 29
Image 29
2175R/2115R

Section 3 - Service and Repair

2175R/2115R

2175WC/2115WC

2175BEV

2175DWRR/2275DWRWS

2275ZWC

(Includes Overlay Models)

GENERAL

Refrigerant is pumped from the compressor to the condenser as a high pressure, high temperature vapor.

As the refrigerant cools in the high pressure condenser, the vapor condenses to liquid. During this phase change, a great amount of heat is rejected with the help of the condenser fan.

The liquid then flows to the dryer where it is strained and filtered.

pressure of the refrigerant is reduced to the evaporating or low side pressure.

The reduction of pressure on the liquid refrigerant causes it to boil or vaporize until it reaches saturation temperature. As the low temperature refrigerant passes through the evaporator coil, it continues to absorb a lot of heat, causing the boiling action to continue until the refrigerant is completely vaporized. It is during this phase that the most heat is absorbed (the cooling takes place) in the refrigerator.

The refrigerant vapor leaving the evaporator travels through the suction line to the compressor inlet. The compressor takes the low pressure vapor and compresses it, increasing both pressure and temperature. The hot high pressure gas is pumped out the discharge line and into the condenser. The cycle continues

From the dryer, the refrigerant flows through the capillary tube which meters the liquid refrigerant to the evaporator. The

COMPRESSOR

CONDENSER

DRYER

EVAPORATOR

CAPILLARY TUBE

ULIN_0280_A

Figure 9. 2175R/2115R/2175WC/2175BEV/2275DWRR/2175DWRR

3-14

Page 29
Image 29
U-Line 2175R/2115R 2175WC/2115WC 2175BEV, 2175DWRR/2275DWRWS 2275ZWC, Includes Overlay Models, Service and Repair, 3-14