4-3-1-4. Change Password

Use this page to change Web Management user password.

4-3-2. Port Configuration

This page can change all port statuses and configure the trunk group.

Press the TAB key to select an item to configure and press SPACE to make a change.

1.State: Current port status. The port can be set to disable or enable mode. If the port setting is disable then it will not receive or transmit any packets.

2.Negotiation: Current auto negotiation setting status of each port.

3.Speed/Duplex: User can set each port for link speed and duplex mode.

4.FC / BP: User can set flow control function to enable or disable. FC (Flow control for full duplex link mode), BP (Backpressure for half duplex mode)

5.Bandwidth In/ Out: For per port packet transmission rate control. Per port level is 100Kbps. It supports individual control method of TX and RX.

6.Priority: Set port to high or low priority.

7.Security: Enable or disable port security function.