Configuring the Serial Interface

Setting the Interface Options

Introduction

This section provides instruction for setting the Interface Options parameter.

V.24 Interface Type Use this procedure to set the Interface Options parameter for V.24 interface type:

Step

Action

Result/Description

 

 

 

1

From the Control Terminal Port

The Port record appears.

 

Main menu, select Configure ->

 

 

Port.

 

 

 

 

2

In the Port Number parameter,

Port 3 is selected.

 

type 3, then press ENTER.

 

 

 

 

3

In the Port Type parameter, type

This defines Port 3 type as FRI.

 

FRI, then press ENTER

 

 

 

 

4

In the Interface Type parameter,

The interface is set to V.24

 

type V.24, and then press

 

 

ENTER.

 

 

 

 

5

In the Interface Options

The Range and Default appears:

 

parameter, type a ?, and then

Range = RI, TM

 

press ENTER.

Default = RI

 

 

 

 

Specify the Pin 22 option:

 

 

RI - V.24 uses Pin 22 for Ring

 

 

Indicator output signal

 

 

TM - V.24 uses Pin 22 for Test

 

 

Mode input signal

 

 

 

6

Select either RI or TM for the

When RI is selected, the output signal

 

Interface Option.

is Ring Indicator.

 

 

When TM is selected, the input signal

 

 

is Test Mode.

 

 

 

3-10