Vanguard Managed Solutions 342 Port DCE Signal Function/Signal DTE Signal Pin Name Using

Models: 342

1 115
Download 115 pages 7.93 Kb
Page 74
Image 74

Cabling the Vanguard 342

DB25 X.21/V.11 Pinouts

Connector Pinout This table shows the DB25 X.21/V.11 connector pinouts for DCE/DTE mode. To use DTE to DTE or DCE to DCE mode, a crossover adapter cable is required. Refer to Figure 3-5 on page 3-21for crossover cable connections:

Port 3

DCE Signal

Function/Signal

Port 3

DTE Signal

Function/Signal

Pin

 

Name

Pin

using

Name

 

 

 

 

Crossover

 

 

 

 

 

Adapter Cable

 

 

 

 

 

 

 

1

-------------

PROTECTIVE

1

-------------

PROTECTIVE

 

 

GROUND

 

 

GROUND

 

 

 

 

 

 

2

<------------

TRANSMITTED

2

------------>

TRANSMITTED

 

 

DATA-A

 

 

DATA-A

 

 

 

 

 

 

3

------------>

RECEIVED DATA-A

3

<------------

RECEIVED DATA-A

 

 

 

 

 

 

4

<------------

CONTROL-A

4

------------>

CONTROL-A

 

 

 

 

 

 

5

-------------

(no connection)

5

-------------

(no connection)

 

 

 

 

 

 

6

------------>

INDICATION-B

6

<------------

INDICATION-B

 

 

 

 

 

 

7

-------------

SIGNAL GROUND

7

-------------

SIGNAL GROUND

 

 

 

 

 

 

8

------------>

INDICATION-A

8

<------------

INDICATION-A

 

 

 

 

 

 

14

<------------

TRANSMITTED

14

------------>

TRANSMITTED

 

 

DATA-B

 

 

DATA-B

 

 

 

 

 

 

15

------------>

SIGNAL ELEMENT

15

-------------

(no connection)

 

 

TIMING-A

 

 

 

 

 

 

 

 

 

16

------------>

RECEIVED DATA-B

16

<------------

RECEIVED DATA-B

 

 

 

 

 

 

17

(no signal)

RECEIVE CLOCK-A

17

(no signal)

RECEIVE CLOCK-A

 

 

 

 

 

 

18

(no signal)

RECEIVE CLOCK-B

18

(no signal)

RECEIVE CLOCK-B

 

 

 

 

 

 

20

<------------

CONTROL-B

20

------------>

CONTROL-B

 

 

 

 

 

 

21

------------>

SIGNAL ELEMENT

21

-------------

(no connection)

 

 

TIMING-B

 

 

 

 

 

 

 

 

 

22

<------------

EXTERNAL

22

------------>

EXTERNAL

 

 

TRANSMIT

 

 

TRANSMIT

 

 

CLOCK B

 

 

CLOCK B

 

 

 

 

 

 

24

<------------

EXTERNAL

24

------------>

EXTERNAL

 

 

TRANSMIT

 

 

TRANSMIT

 

 

CLOCK A

 

 

CLOCK A

 

 

 

 

 

 

25

--------------

(no connection)

25

-------------

(no connection)

 

 

 

 

 

 

Note

To use DTE mode, the Interface Options parameter must be set to XOVER. For details on setting the X.21/V.11 Interface Options, see “Setting the Interface Options” section on page 3-10.

3-20

Installation and Replacement

Page 74
Image 74
Vanguard Managed Solutions 342 Port DCE Signal Function/Signal DTE Signal Pin Name Using, TIMING-A Received DATA-B