Accessing the Control Terminal Port

Accessing the Control Terminal Port

Introduction

 

 

 

Once you have powered on the Vanguard 342, you can access the Control Terminal

 

Port from the PC or terminal attached to the CTP port.

 

This section does not provide all information about accessing the CTP. For more

 

information on accessing and using the CTP refer to the Vanguard Basic

 

Configuration Manual (Part Number T0113).

Procedure

 

 

 

Follow these steps to access the Vanguard 342 CTP Main menu:

 

 

 

Note

 

 

 

 

 

 

This procedure assumes that a PC or terminal is connected to the Vanguard 342 using the CTP access cable.

Step

Action

1Set your terminal, or terminal emulation software, to VT100, 9600 bps, 8 bit, no parity, 1 stop bit.

2Type <CR> until either an asterisk (*) or the OK prompt appears.

3When you see OK, type atds0 <CR>. When you see the asterisk (*) type

.ctp.

The CTP banner will appear. If this banner does not appear, verify that these steps have been followed correctly.

4Type <CR> at the password prompt, if no password has been set.

CTP Access Using

Another way to connect to the CTP, after the node is configured and operational, is to

Remote Telnet

access remotely via your established IP network by telneting into the node from an

 

 

IP network-based personal computer or workstation. You can create a telnet session

 

 

from your PC to the target node using and IP address configured in that node.

 

 

Connect to the CTP by entering atds0 <CR> after the Vanguard 342 outputs the OK

 

 

prompt on your Telnet terminal window.

CTP Access Using

 

If the Vanguard 342 is operating in an X.25 network, or if Frame Relay Annex-G is

Remote X.25 or

used to connect with other VanguardMS Network Access Product nodes, you can

Frame Relay

access the Vanguard CTP remotely by making a Switched Virtual Circuit (SVC) call

Network

to the node and specifying subaddress 98.

 

 

For example:

 

 

• If you are using ASYNC PAD, type 10198 at the asterisk (*) prompt, and

 

 

then press Enter.

 

 

• If you are using AT PAD, type atds010198, and then press Enter.

 

 

 

Powering Up and Loading Software

4-7

Page 95
Image 95