Configuring the Serial Interface

V.35/V.36, and X.21/ Use this procedure to set the Interface Options parameter for V.35, V.36, and

V.11 Interface X.21/V.11 interface types:

Types

Step

Action

Result/Description

 

 

 

 

 

1

From the Control Terminal Port

The Port record appears.

 

 

Main menu, select Configure ->

 

 

 

Port.

 

 

 

 

 

 

2

In the Port Number parameter, type

Port 3 is selected.

 

 

3, then press ENTER.

 

 

 

 

 

 

3

In the Port Type parameter, type

This defines Port 3 type as FRI.

 

 

FRI, then press ENTER

 

 

 

 

 

 

4

In the Interface Type parameter, type

The interface is set to the selected

 

 

one of these interfaces: V.35, V.36,

type.

 

 

X.21 and then press ENTER.

 

 

 

 

 

 

5

In the Interface Options parameter,

The Range and Default appears:

 

 

type a ?, and then press ENTER.

Range = NONE, XOVER

 

 

 

Default = NONE

 

 

 

Specify the cable type:

 

 

 

NONE - V35/V.36/X.21 DCE

 

 

 

with straight through cable

 

 

 

XOVER - V35/V.36/X.21 DCE

 

 

 

with crossover adapter cable

 

 

 

 

 

6

Select either NONE for straight

When NONE is selected, the serial

 

 

DCE mode, or XOVER when using

interface is in straight DCE mode.

 

 

the DTE crossover adapter cable.

When XOVER is selected, the

 

 

 

serial interface is in DCE Mode

 

 

 

using the adapter cable.

 

 

 

 

 

 

 

 

 

Installation and Replacement

3-11

Page 65
Image 65
Vanguard Managed Solutions 342 installation manual Types