VXI Technology, Inc.
INPUT:DEBOUNCE
The INPut:DEBounce command sets the time period for the digital debounce circuitry. This command affects all the 16 channels of the instrument. It is important to note that the debounce resolution is 9.6 ∝s.
INPut:DEBounce <value> | Where <value> ranges from 9.6 ∝s, i.e., |
| 0.0000096 s to 0.6291456 s. |
|
|
EXAMPLES |
|
INPut:DEBounce | Sets the input debounce time for all |
| channels to 0.0000096 s. This will not |
| allow a signal to generate an interrupt |
| unless the input signal crosses the signal for |
| more than 9.6 |
INP:DEB 0.6 | Setting input debounce time to 0.6 s. |
INP:DEB? | Returns the input debounce time as 0.6 s. |
0.6 |
|
26 | VM4016 Programming |