APPLICATION EXAMPLES

This section contains examples of using SCPI command strings for programming the VM4016 module. The code is functional and will contain a brief description about the operation.

Example 1

In this example, the VM4016 sets the output interrupt polarity on the front panel and the debounce time period for the digital debounce circuitry.

OUTPut:POLarity:EXTernal:INTerrupt NORM

Sets the external interrupt output polarity to

 

high pulse when an interrupt occurs.

INPut:DEBounce 25e-6

Sets input debounce time for all channels to

 

25 s. This will not allow a signal to

 

generate an interrupt unless the channel is

 

active for greater than 25 s.

Example 2

In this example, the VM4016 enables or disables the specified channels for interrupt generation, sets the offset, polarity and voltage range. It returns the value of First Latched register which records the first input channel to cross its threshold and queries the current state of inputs.

INP:MASK 1,(@1,2)

Enables Channels 1 and 2 for interrupt

 

generation.

INP:MASK 0,(@3:16)

Disables Channels 3 through 16 from

 

generating an interrupt.

INP:RANG 10,(@1,2)

Selects ±10 volts as the input range for

 

Channel 1 and 2.

INP:OFFS +5.25,(@1,2)

Selects +5.25 volts as the offset voltage for

 

Channels 1 and 2.

INP:POL NORM,(@1,2)

Selects both Channel 1 and 2 to generate an

 

interrupt when Channels 1 and 2 are

 

greater than the offset voltage.

FETC:LATC?

Returns the active signal in the First

 

Latched Register.

FETC:RAW?

Returns the State of unconditioned

65535

 

(ummasked and non-inverted) inputs.

FETC:COND?

Returns the state of masked and inverted

3

 

inputs.

34

VM4016 Programming

Page 34
Image 34
VXI VM4016 user manual Application Examples