www.vxitech.com

ViPInt16 first_latched_reg

-This parameter returns the first input channel which crosses the programmed threshold voltage.

ViPInt16 raw_data

-This returns the 16 bit value that represents the current unconditioned [raw] state of the inputs.

ViPInt16 conditioned_data

-This returns the 16 bit value that represents the current conditioned state of the inputs.

Return Values:

Returns VI_SUCCESS if successful, else returns error

 

value.

 

Description

This is an application function that shows how

the

 

user can use core functions to enable/disable the

 

specified channels for interrupt generation and

 

configure the specified channels’ various parameters

 

such as offset, polarity and voltage-range.

It

 

returns the value of the First Latched register which

 

records the first input channel to cross its threshold

 

and queries the current state of the inputs.

Note

that this function resets the module to its default state.

***************************************************************************/

ViStatus_VI_FUNC vtvm4016_setup_and_read_data(ViSession instr_hndl,

ViInt16 channel_list[],ViInt16 num_of_channels,ViReal32 offset[],ViInt16 polarity[],ViInt16 voltage_range[], ViPInt16 first_latched_reg,ViPInt16 raw_data,

ViPInt16 conditioned_data)

{

/* Variable used to store return status of the function */ ViStatus status = VI_NULL;

/* Reset to the default state */

status = vtvm4016_reset(instr_hndl);

if (status < VI_SUCCESS) return status;

/* Function to enable the selected channels to cause interrupt */ status = vtvm4016_enable_disable_channels (instr_hndl,

vtvm4016_ENABLE_CHANNEL, channel_list, num_of_channels); if (status < VI_SUCCESS)

return vtvm4016_ERROR_MASK_OR_UNMASK_CHANNELS;

VM4016 Programming

45

Page 45
Image 45
VXI user manual VM4016 Programming