Weil-McLain 550-141-850/0599 manual Bottom side of boiler front section, White side propane plate

Models: GOLD DV WATER BOILER 550-141-850/0599

1 96
Download 96 pages 38.64 Kb
Page 19
Image 19
White side (propane plate)

Installation • Start-Up • Parts • Maintenance

Figure 5b Checking and replacing gas/air orifice plate. For propane installations, replace silver plate with red/white propane plate.

 

DO NOT use electric or

threaded holes could strip out, causing

 

 

pneumatic screwdrivers to

an inadequate seal of the orifice plate.

 

 

remove or tighten the gas/air boss

Failure to properly seal the plate to

 

screws. Hand-tighten only, using

the housing could result in a gas leak,

 

manual screwdriver. Should the

causing severe personal injury, death

 

torque exceed 40 inch-pounds, the

or substantial property damage.

 

 

 

 

 

 

 

 

 

 

White side (propane plate)

 

Warning label side (natural gas)

 

 

(Install with this side

 

toward air inlet hose)

 

Gas/air manifold

Bottom side of boiler front section

PROP GVX

Propane — red side

Natural — plain side

Install plate with red side (propane) or plain side (natural) against the blower housing.

Orifice plate after bending along score mark. This makes the plate identification readable after

installation.85004b

Part number 550-141-850/0699

19

Page 19
Image 19
Weil-McLain 550-141-850/0599 Bottom side of boiler front section, •Installation • Start-Up• Parts • Maintenance, Prop Gvx