VI Field wiring
Electrical installation must comply with:
National Electrical Code and any other national, state, provincial or local codes or regulations.
In Canada, C.S.A. C22.1 Canadian Electrical Code Part 1, and any local codes.
Wiring must be N.E.C. Class 1.
If original wiring as supplied with boiler must be replaced, use only type 90 °C wire or equivalent.
Boiler must be electrically grounded as required by National Electrical Code ANSI/NFPA
Wiring connections
Thermostat(s)
Install on inside wall away from influences of drafts, hot or cold water pipes, lighting fixtures, television, sunrays, or fireplaces.
Follow instructions with thermostat. If it has a heat anticipator, set heat anticipator in thermostat to match power requirements of equipment connected to it (ignition control and gas valve, zone valve contacts, etc.). Wiring diagram on boiler gives setting for standard equipment (ignition control and gas valve).
Thermostat wires are labeled
For zoned systems, substitute the zone valve end switches or circulator relay contacts for the thermostat contact shown in Figure 18.
When using
Junction Box (furnished)
Mount the 2 x 4 junction box on the left side of the boiler as shown on page 3 of this manual and in other illustrations.
Fused disconnect or service switch (15 amp. recommended) may be mounted on this box. For those installations with local codes which prohibit installation of fused disconnect or service switch on boiler, install a 2 x 4 cover plate on the boiler junction box and mount the service switch remotely as required by the code.
Connect 120 VAC power wiring as shown in Figure 18.