IIIh Water piping — multi-zone radiant system
Figure 14a Manual bypass; fixed temp
operation only
Zone 2
Multi-zone radiant heating system piping
12" |
max |
Zone 1
Cold water
fill
Figure 14b (circulator zoning) show suggested piping for these systems.
Select an automatic temperature control valve or motor- operated valve which can be adjusted for the desired supply water temperature.
Circulator zoning — The GV internal circulators must not be removed. Provide a separate circulator for each zone.
GV Boiler
85015b
Figure 14b Auto return temp regulation; outdoor reset or fixed temp
Zone 2
Outdoor reset control
Apply Figure 14a or 14b for any system intended for outdoor reset of the supply water temperature. Use a
Legend
12" |
max |
Zone 1
Cold water
fill
1 | Boiler isolation valves |
2 | Automatic air vent (with |
| expansion tank), or connect to tank fitting |
| |
3 | Diaphragm- or |
| used (For |
| from top of air separator to tank fitting as in |
| Figure 10.) |
4 | Zone valve |
5 | System or zone circulator |
6 | Flow/check valve |
7 | Hose bibb purge valve |
8 | Boiler pressure/temperature gauge |
GV Boiler
85018b
9 | System supply temperature gauge |
10 | Boiler return temperature gauge |
13Supply temperature automatic mixing valve
34 | Part number |