Figure 18 Field wiring connections — service switch and thermostat (or end switch) provided by installer

Field wiring

Factory wiring

120 VAC

 

 

Hot

Neutral

Ground

Thermostat

or end switch

(not provided)

Service switch

(not provided)

 

 

Ground screw

 

Wire nuts

Black

White

Green

Black

Black

 

 

T h e r mo s t a t

Junction box,

 

leads, through

boiler left side

 

jacket left side

 

 

85028

 

 

Service switch

(not provided)

Thermostat or end switch

(not provided)

For your safety, turn off electrical power supply at

 

Wiring must be N.E.C. Class 1.

service entrance panel before making any

electrical connections to avoid possible electric shock hazard. Failure to do so can cause severe personal injury or death.

Watch polarity of the circuit when connecting the 120 VAC power wiring. If the polarity is switched, the boiler control module will lockout. The control module will flash the POWER light to indicate this problem. See Troubleshooting, manual Section XI.

If original wiring as supplied with boiler must be replaced, use only type

105°C wire or equivalent.

Boiler must be electrically grounded as required by National Electrical Code ANSI/NFPA 70-latest edition.