Western Telematic CMS-16 manual Connecting Devices to the CMS, Application Example

Models: CMS-16

1 62
Download 62 pages 40.13 Kb
Page 17
Image 17

4.4. Connecting Devices to the CMS

1.Access the Command Mode.

2.Determine which port will be used for connection to the new device (e.g. Port 3).

3.Check Buffer: Type /S [Enter] to display the Port Status Screen. Check the "Buffer Count" column, which lists the amount of data stored in the buffer for each port.

. If the Port Status Screen shows data stored in the buffer for the desired port, type /E xx [Enter] to clear the buffer (where xx is the desired port number).

b.Note that cleared data cannot be recovered.

4.Use an appropriate DB9 cable to connect the RS232 serial port on the device to a DB9 port on the CMS.

. External Modems and other DCE Devices: Use a standard serial modem cable.

b.PCs and other DTE Devices: Use a standard null modem cable.

5.Select communication parameters for each port as described in Section 5.

4.5. Application Example

Page 17
Image 17