Enter: "<" Previous Port,

">" Next Port,

<ESC> Exit ...

Figure 5.2: Port Configuration Menu (Modem Mode)

When Port Mode (menu Item 7) is set to Modem Mode, the menu will include additional prompts (see Figure 5.2), which are used to define the following:

71. Reset String: If necessary, this prompt can be used to re-define the modem reset string. The Reset String is sent prior to the Initialization string in order to select common initial parameters. (Default = ATZ).

72. Initialization String: Defines a command string that is sent after the Reset String to initialize a modem to settings required by your application. (Default =

AT&C1$D2S0=1).

73. Hang-Up String: Defines the modem hang-up message. Although the CMS will pulse the DTR line in order to hang-up an attached modem, the Hang-Up string is often useful for controlling modems that do not use the DTR line. (Default = undefined).

8. Supervisor Mode: Permits or denies port access to Supervisor Mode. When this item is enabled (Permit), and the valid Supervisor Password is entered, the port will be allowed to invoke Supervisor Level commands. If this item is disabled (Deny), the port may not enter Supervisor Mode, even when the Supervisor Password is entered. (Default = Permit).

9. Logoff Character: Defines the Logoff Character for this port. The Logoff Character determines the command sequence that must be issued at this port in order to disconnect from a second port (Resident Disconnect). Note the following:

The default Logoff Character is "+". As a result, the default Resident Disconnect Sequence is [Enter]+++[Enter].

The default three character Resident Disconnect Sequence uses the format

"[Enter]LLL[Enter]", where L is the Logoff Character. If the one character disconnect is selected (see item 10), a resident connection is terminated by simply typing the Logoff Character once (without carriage returns).

10. Sequence Disconnect: Enables/Disables and configures the Resident Disconnect command. This prompt offers the option to either disable the Sequence Disconnect, select a three character format, or select a one character format. (Default = Three Characters). Note the following:

Page 27
Image 27
Western Telematic CMS-16 manual AT&C1$D2S0=1