Westinghouse 190/5300 manual Take Apart Power Supply Board 5300 Series Only

Models: 190/5300

1 186
Download 186 pages 42.11 Kb
Page 118
Image 118

Take Apart

Power Supply Board (5300 Series Only) - 46

 

 

 

Power Supply

Board Insulator

Power Supply

Board (5300 Series only)

Backup Battery Cable Connector

1Disconnect the backup battery cable from the power supply board by carefully pulling the male portion of the connector to the right.

2Lift the power supply board straight up, supporting all sides of the board (the power supply board connector is under the backup battery connector).

Caution: Make certain that the power supply board insulator is present and correctly placed when you reinstall the board.