Troubleshooting

 

Symptom Charts/Power - 5

 

 

is blank;

1

If sleep LED is continually on, backup battery power has

 

Screen

computer doesn't

 

been interrupted. Restart computer by holding down reset

respond

 

actuator 10-20 seconds. If computer doesn’t restart, repeat

 

 

 

2

3–4 times.

 

 

 

Restart computer.

 

 

 

3

Disconnect power adapter, remove battery, and restart

 

 

 

4

computer in 3-4 minutes.

 

 

 

Check power adapter cable.

 

 

 

5

Try known–good, charged battery.

 

 

 

6

Test fuse on logic board to make sure it is not open.

 

 

 

7

Try known-good power adapter. (See Power Information in

 

 

 

8

Basics chapter.)

 

 

 

Reset power manager.

 

 

 

9

Check all logic board cables and connections.

 

 

 

10

Replace keyboard.

 

 

 

11

Replace power supply board (5300 Series only).

 

 

 

12

Replace logic board.