Westinghouse 190/5300 manual Display

Models: 190/5300

1 186
Download 186 pages 42.11 Kb
Page 49
Image 49

 

 

Troubleshooting

 

Symptom Charts/Video - 10

 

 

stopped

1

PowerBook 190 Series, 5300/100, 5300cs/100: If

 

Display

working or dimmed

 

temperature is under 0° C or over 50° C, this reaction is

but is fine now

 

normal. Let screen warm up for 30 minutes. If symptom

 

 

 

2

persists, replace display.

 

 

 

PowerBook 5300c/100 and 5300ce/117: replace display.

Backlight doesn't

1

Adjust screen contrast and brightness settings.

operate

2

Verify that backlight cable connection is secure.

 

 

 

3

Check cable, inverter board, and logic board connections.

 

 

 

4

Verify that cables are not pinched or severed.

 

 

 

5

Replace inverter board.

 

 

 

6

Replace display.

 

 

 

7

Replace logic board.

 

 

 

 

Ê

 

Page 49
Image 49
Westinghouse 190/5300 manual Display