Worth Data 701 RF manual While PromptNET/ActiveX will intercept

Models: 701 RF

1 155
Download 155 pages 44.3 Kb
Page 86
Image 86

OnTermNotSignedIn

Data passed:

basename, channel, terminal

Event:

A command has been sent to a terminal that is not

 

signed in.

OnTermSequenceError

Data passed:

basename, channel, terminal

Event:

The one-for-one host prompt/terminal response

 

protocol has been violated. The host cannot send a

 

second Input command until it has received a response

 

from the first Input command. If a base station receives

 

5 sequence errors in a row, a Host Logic error is

 

generated and the base shuts itself down.

 

While PromptNET/ActiveX will intercept and

 

prevent most logic errors, they are still possible so

 

you should implement this event handler!

OnTermIllegalCommand

Data passed:

basename, channel, terminal

Event:

An illegal command has been sent to a terminal.

 

PromptNET/ActiveX is designed to prevent illegal

 

commands but we may not have imagined all the

 

ways in which our customers will want to use it!

OnTermUpArrow

 

Data passed:

basename, channel, terminal

Event:

The up-arrow button has been pressed on a

 

terminal. You must issue another Input method call

 

before WDIPterm can respond to another keypress

 

on this terminal.

OnTermDownArrow

Data passed:

basename, channel, terminal

Event:

The down-arrow button has been pressed on a

 

terminal. You must issue another Input method call

 

before WDIPterm can respond to another keypress

 

on this terminal.

OnTermLeftArrow

 

Data passed:

basename, channel, terminal

Event:

The left-arrow button has been pressed on a

 

terminal. You must issue another Input method call

6-31

Page 86
Image 86