OutputSerial

 

Parameters:

data

Function:

This instructs the ActiveTerminal to send data to the

 

terminal’s serial port. Data must be less than 231

 

characters in length for each call to OutputSerial.

SendDisplay

 

Parameters:

line, position, prompt

Function:

This instructs the ActiveTerminal to display the

 

prompt at line and position. Must be followed by an

 

"Input" method call to take effect.

ClearScreen

 

Function:

This instructs the ActiveTerminal to clear its

 

display. Must be followed by an "Input" method

 

call to take effect.

ClearLine

 

Parameters:

line

Function:

This instructs the ActiveTerminal to clear the

 

specified line on its display. Must be followed by

 

an "Input" method call to take effect.

SendDate

 

Parameters:

line

Function:

This instructs the ActiveTerminal to display date

 

and time on the specified line number. Must be

 

followed by an "Input" method call to take effect.

Beep

 

Parameters:

count

Function:

This instructs the ActiveTerminal to beep count

 

times. Count may be a value from 1 to 9. Must be

 

followed by an "Input" method call to take effect.

6-19

Page 74
Image 74
Worth Data 701 RF manual Data, Line, Count