Code 39 Advanced Features and Functions

Mod 43 Check Character

Standard Code 39 can be printed with a "Mod 43 Check Character". This Mod 43 check character cannot be used with Full ASCII Code

39. Assigning a value to each character in the data to be bar coded from the table as follows derives the check character:

Char

value

Char

value

Char

value

 

Char

value

 

0

0

B

11

M

22

 

X

33

1

1

C

12

N

23

 

Y

34

 

2

2

D

13

O

24

 

Z

35

 

3

3

E

14

P

25

-

36

4

4

F

15

Q

26

.

37

5

5

G

16

R

27

 

space

38

 

6

6

H

17

S

28

$

39

7

7

I

18

T

29

/

40

8

8

J

19

U

30

+

41

9

9

K

20

V

31

%

42

A

10

L

21

W

32

 

 

 

 

 

 

Mod 43 Check character calculation for Code 39

Here is an example to illustrate how the check character is calculated for bar code data of 123XYZ:

1. Take the sum of the values assigned to each character:

1 + 2 + 3 + 33 + 34 + 35 = 108

1 2 3 X Y Z

2.Divide the sum by 43: (thus the name modulus 43)

108/43 = 2 with a Remainder of 22

3.Find the character corresponding with the remainder.

M (value 22) is the CHECK CHARACTER

The data becomes 123XYZM, with M added as the Mod-43 check character.