Installing the System Control Panel

WARNING: Fire hazard

The System Control Panel is not ignition protected. Do not install in areas requiring ignition-protected equipment.

WARNING: Shock hazard

Before making an opening in a wall, bulkhead, or panel, ensure there is no wiring or other obstruction within the wall.

To mount the System Control Panel:

1.Peel the backing from the supplied mounting template sticker and place it in your chosen installation location. Use the template to mark locations for the mounting holes and the area to be cut out.

2.Pilot-drill the mounting holes (if necessary, depending on your mounting surface) and, using a jigsaw, cut out the hole in which the System Control Panel will be inserted.

3.Route the network cable(s) from other Xanbus-enabled devices inside the wall and through the opening.

CAUTION: Equipment damage

Connect the System Control Panel only to other Xanbus compatible devices.

:

Although the cabling and connectors used in this network system are the same as Ethernet connectors, this network is not an Ethernet system. Equipment damage may result from attempting to connect these two different systems.

4.Connect the network cable(s) (and terminator if necessary) to either input on the back of the System Control Panel. See Figure 2-1.

Connect one network cable and a network terminator to the System Control Panel if it is the last device at the end of a daisy chain-type network layout. Refer to the Xanbus System Installation Guide for more information.

5.Place the unit in the opening and secure it with four #6 screws.

6.Peel off the protective plastic coating covering the screen and indicator lights.

975-0083-01-01

2–3

Page 21
Image 21
Xantrex Technology 809-0910 manual To mount the System Control Panel, Installing the System Control Panel