Operation

Types of fault messages

continuecancel

Figure 5-8System Control Panel fault message

There are two types of System Control Panel fault messages: automatic and manual. For a list of faults and their associated types, refer to Chapter 6, “Troubleshooting”.

Automatic faults clear themselves automatically if the fault condition goes away.

Manual faults require you to clear them by:

selecting Clear Faults on the menu of the device that generated the fault (if the fault condition still exists, the fault message will reappear).

correcting the condition that caused the fault.

Viewing the System Control Panel fault log

The fault log lists the most recent System Control Panel faults, up to a total of 20. On each line, the log shows the fault code, the date the fault occurred, and the time the fault occurred.

To view the fault log:

1.On the System Panel advanced menu, press the down arrow button to highlight Fault log.

2.Press Enter.

Figure 5-9System Control Panel fault log

5–12