Page 150 of 456 Installing Power Failure Transfer Units

2For each trunk assigned to the PFTU.

Connect the tip and ring of the CO card to the third pair of the assigned PFTU.

Connect the tip and ring of the trunk to the fourth pair of the assigned PFTU.

End of Procedure

Installing QUA6 PFTUs

QUA6 PFTUs are used for Large System installations. The QUA6 PFTU is powered from an auxiliary –48 V DC fused output from the external power equipment.

Figure 60 on page 146 shows a high-level view of QUA6 PFTU alarm connections. For PFTU operation, the wiring from the following equipment cross-connects through termination areas at the MDF:

1PFTU

2Auxiliary –48 V DC

3System monitor

4Attendant console (optional)

5Designated telephones

6Central Office trunks

NN43021-310 Standard 02.01 December 2007

Page 150
Image 150
Nortel Networks 1000M warranty Installing QUA6 PFTUs