Page 396 of 456 Installing a Signaling Server

Figure 140

IBM X306m Signaling Server (rear view)

Note: Refer to Figure 140 when performing the following procedure.

Procedure 76

Connecting an IBM X306m Signaling Server

1Connect the Signaling Server to the TLAN subnet. Insert the RJ-45 CAT5 (or better) cable into Port 1 (TLAN network interface) on the back of the Signaling Server. Port 1 is the right-most of the two network interfaces.

2Connect the Signaling Server to the ELAN subnet. Insert the RJ-45 CAT5 (or better) cable into PEthernet 2 connector (ELAN network interface) on the back of the Signaling Server. Port 2 is the left-most of the two network interfaces.

3Connect a DTE–DTE null modem serial cable from the serial port on the back of the Signaling Server to the serial port on a maintenance terminal.

4Connect the Signaling Server power cord.

a.Check that the power cord is the type required in the region where the Signaling Server is used. Do not modify or use the supplied AC power cord if it is not the correct type.

b.Attach the female end of the power cord to the mating AC power receptacle on the left side of the Signaling Server’s back panel. Plug the male end of the AC power cord into the AC power source (wall outlet).