Adding a module to a column Page 381 of 456

7Install the perforated panel and top cap on the module being added:

a.Position the perforated panel and slide it slightly to the right (at the rear). Install the screw that secures the panel and LED bracket.

b.Position wiring from the perforated panel so it rests in the cable well located next to the orange power connector at the rear of the module (see Figure 137 on page 381).

Figure 137

Cable well location

Cable well Orange connector

Top of module

Bracket

View at rear of module

553-5889

c.Position the top cap and install the bolts that secure it.

d.Replace the air exhaust grills at the front and rear of the top cap.

8Reconnect power to the top cap:

a.Connect the system monitor cable to J2 on the backplane. Line up the alignment tab on the connector and snap on the pin headers to position the connector correctly (see Figure 138 on page 381).

Figure 138

Monitor cable J2 backplane alignment tab and key alignment

Alignment tab on backplane connector

Side view of connectors

Key on cable connector

553-5885

Communication Server 1000M and Meridian 1 Large System Installation and Commissioning

Page 381
Image 381